{"id":5229,"date":"2023-08-23T23:44:04","date_gmt":"2023-08-23T23:44:04","guid":{"rendered":"https:\/\/www.hangzhiprecision.com\/?p=5229"},"modified":"2026-01-23T02:10:11","modified_gmt":"2026-01-23T02:10:11","slug":"current-transducer-vs-current-transformer","status":"publish","type":"post","link":"https:\/\/www.hangzhiprecision.com\/en_gb\/knowledge-center\/current-transducer-vs-current-transformer\/","title":{"rendered":"Current transducer vs current transformer"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5229\" class=\"elementor elementor-5229\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8b8c5f1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8b8c5f1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2d3c0f4\" data-id=\"2d3c0f4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-075ba74 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"075ba74\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-a42c491\" data-id=\"a42c491\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-57edd5e elementor-widget elementor-widget-heading\" data-id=\"57edd5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What are differences between current transducers and Current transformers? <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-3eca419 elementor-widget elementor-widget-spacer\" data-id=\"3eca419\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0079db elementor-widget elementor-widget-text-editor\" data-id=\"b0079db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.hangzhiprecision.com\/en_gb\/current-sensors-and-current-transducers\/\">Current transducers<\/a> and current transformers are utilised for the purpose of measuring electrical currents; yet, they exhibit distinctions in terms of their operational principles, applications, and inherent traits.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-ac1c785 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ac1c785\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3cf4ba8\" data-id=\"3cf4ba8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5416e9b elementor-widget elementor-widget-image\" data-id=\"5416e9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.hangzhiprecision.com\/en_gb\/products\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png\" class=\"attachment-medium size-medium wp-image-28\" alt=\"AIT400-SG HIGH PRECISION CURRENT TRANSDUCER\" srcset=\"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png 300w, https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-150x150.png 150w, https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708.png 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Current Transducers<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-b4052bf\" data-id=\"b4052bf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b6cc49f elementor-widget elementor-widget-image\" data-id=\"b6cc49f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/current-transformer-300x300.jpg\" class=\"attachment-medium size-medium wp-image-5317\" alt=\"current transformer\" srcset=\"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/current-transformer-300x300.jpg 300w, https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/current-transformer-150x150.jpg 150w, https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/current-transformer-12x12.jpg 12w, https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/current-transformer.jpg 500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Current Transformer<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-f961123 elementor-widget elementor-widget-heading\" data-id=\"f961123\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Working Principle of current transformer and current transducer:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b6aeb0 elementor-widget elementor-widget-text-editor\" data-id=\"2b6aeb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Current Transformers (CTs) operate based on the fundamental principle of electromagnetic induction. The transformers are composed of a primary winding, which facilitates the passage of the current to be measured, and a secondary winding, which is utilised to measure the induced current. The current transformation ratio is determined by the ratio between the main and secondary windings.<\/p><p><a href=\"https:\/\/www.hangzhiprecision.com\/en_gb\/current-sensors-and-current-transducers\/\">Current transducers<\/a> employ several concepts, such as the Hall effect, <a href=\"https:\/\/ieeexplore.ieee.org\/document\/8601521\">fluxgate<\/a>, shunt resistors, Rogowski coils, or other magnetic phenomena, in order to directly quantify the current and transform it into a detectable output.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5415110 elementor-widget elementor-widget-heading\" data-id=\"5415110\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Measurement Range:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f440a0 elementor-widget elementor-widget-text-editor\" data-id=\"7f440a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Current transformers (CTs) are frequently employed in applications that involve high currents, such as power distribution networks or industrial equipment, where the primary current is of considerable magnitude.<\/p><p>Current transducers are capable of being engineered to accommodate a broad spectrum of current levels, spanning from low magnitudes to elevated magnitudes, contingent upon the particular type and configuration.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20a0636 elementor-widget elementor-widget-heading\" data-id=\"20a0636\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Accuracy and Linearity:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3eac45 elementor-widget elementor-widget-text-editor\" data-id=\"c3eac45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Current transformers (CTs) are often characterised by a high level of accuracy and linearity within their designated range. High-accuracy applications in power systems, where precision plays a crucial role, frequently employ them.<\/p><p>The accuracy and linearity of current transducers may exhibit variability contingent upon their specific type and design characteristics. Certain forms of transducers, such as <a href=\"https:\/\/www.hangzhiprecision.com\/en_gb\/products\/\">fluxgate current transducers<\/a>, have the capability to offer high levels of precision and linearity. Conversely, there are other types of transducers that may possess certain limits in these aspects.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d381f8 elementor-widget elementor-widget-heading\" data-id=\"9d381f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">4. Size and Form Factor:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf8aff elementor-widget elementor-widget-text-editor\" data-id=\"daf8aff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Current transformers (CTs) are generally characterised by their larger and bulkier physical dimensions, which can be attributed to the structure of their windings and the presence of a magnetic core. The purpose of their design is to form a circular or surrounding path around the conductor via which the electric current flows.<\/p><p>Current transducers are capable of being created in a multitude of sizes and form factors, encompassing both small and non-intrusive configurations.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdc9ffb elementor-widget elementor-widget-heading\" data-id=\"fdc9ffb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">5. Isolation:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa9d656 elementor-widget elementor-widget-text-editor\" data-id=\"fa9d656\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Current transformers (CTs) provide galvanic isolation between the primary and secondary circuits. The implementation of isolation serves to prevent the establishment of a direct electrical connection between the measured current and the equipment utilised for measurement purposes.<\/p><p>Current transducers can be categorised into two sorts based on their galvanic isolation capabilities. While certain current transducers do provide galvanic isolation, it is important to note that not all types of current transducers offer this capability. The determination of feasibility is contingent upon the precise design and application criteria.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35a6aa5 elementor-widget elementor-widget-heading\" data-id=\"35a6aa5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">6. Applications:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be534e8 elementor-widget elementor-widget-text-editor\" data-id=\"be534e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>CTs: Industrial Current transformers are commonly used for metering, protection, and control in electrical systems. Current-based relays and protective devices require them.<\/p><p>Current Transducers Current transducers are utilised in a variety of applications, such as industrial automation, motor control, battery monitoring, and renewable energy systems, among others.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a0a33a elementor-widget elementor-widget-text-editor\" data-id=\"1a0a33a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In conclusion, while both current transformers and current transducers measure electrical currents, their working principles, ranges, accuracies, and applications are distinct. The choice between the two depends on the application-specific requirements and the required characteristics for precise and dependable current measurement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-45d2d4d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"45d2d4d\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1be6ed2\" data-id=\"1be6ed2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e66b217 elementor-widget elementor-widget-heading\" data-id=\"e66b217\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Get in touch with our experts<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edb1642 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"edb1642\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57f7ecb elementor-widget elementor-widget-shortcode\" data-id=\"57f7ecb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\t\t<div data-elementor-type=\"section\" data-elementor-id=\"8223\" class=\"elementor elementor-8223\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6538c7ed elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6538c7ed\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7c75eba2\" data-id=\"7c75eba2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-63f8b87 elementor-widget elementor-widget-text-editor\" data-id=\"63f8b87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tContact us directly via email <a href=\"mailto:info@hangzhiprecision.com\"><strong>info@hangzhiprecision.com<\/strong><\/a> or fill out the form below. We will respond as soon as possible.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5d3cbf elementor-widget elementor-widget-shortcode\" data-id=\"f5d3cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f7572-o1\" lang=\"en\" dir=\"ltr\" data-wpcf7-id=\"7572\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en_gb\/wp-json\/wp\/v2\/posts\/5229#wpcf7-f7572-o1\" method=\"post\" class=\"wpcf7-form init cf7skins cf7t-event cf7s-default\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/en_gb\/wp-json\/wp\/v2\/posts\/5229#wpcf7-f7572-o1\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"7572\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f7572-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<fieldset>\n\t<legend>hangzhi<\/legend>\n\t<ol>\n\t\t<li><label for=''>Name: <em class=\"cf7s-reqd\">*<\/em> <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"cf7s-name\" \/><\/span><\/li>\n\t\t<li><label for=''>Phone: <em class=\"cf7s-reqd\">*<\/em> <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-phone\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"tel\" name=\"cf7s-phone\" \/><\/span><\/li>\n\t\t<li><label for=''>Email: <em class=\"cf7s-reqd\">*<\/em> <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"cf7s-email\" \/><\/span><\/li>\n\t\t<li><label for=''>Company: <em class=\"cf7s-reqd\">*<\/em> <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-Company\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"cf7s-Company\" \/><\/span><\/li>\n\t\t<li><label for=''>Enquire about: <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-products\"><span class=\"wpcf7-form-control wpcf7-checkbox\"><span class=\"wpcf7-list-item first\"><input type=\"checkbox\" name=\"cf7s-products[]\" value=\"High Precision Current Transducers\" \/><span class=\"wpcf7-list-item-label\">High Precision Current Transducers<\/span><\/span><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"cf7s-products[]\" value=\"High Precision Voltage Transducers\" \/><span class=\"wpcf7-list-item-label\">High Precision Voltage Transducers<\/span><\/span><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"cf7s-products[]\" value=\"Electrical Measurement Instrument\" \/><span class=\"wpcf7-list-item-label\">Electrical Measurement Instrument<\/span><\/span><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"cf7s-products[]\" value=\"Solutions\" \/><span class=\"wpcf7-list-item-label\">Solutions<\/span><\/span><span class=\"wpcf7-list-item last\"><input type=\"checkbox\" name=\"cf7s-products[]\" value=\"Other\" \/><span class=\"wpcf7-list-item-label\">Other<\/span><\/span><\/span><\/span><\/li>\n\t\t<li><label for=''>Information request: <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-Information\"><span class=\"wpcf7-form-control wpcf7-checkbox\"><span class=\"wpcf7-list-item first\"><input type=\"checkbox\" name=\"cf7s-Information[]\" value=\"Price\" \/><span class=\"wpcf7-list-item-label\">Price<\/span><\/span><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"cf7s-Information[]\" value=\"Datasheet\" \/><span class=\"wpcf7-list-item-label\">Datasheet<\/span><\/span><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"cf7s-Information[]\" value=\"User Manual\" \/><span class=\"wpcf7-list-item-label\">User Manual<\/span><\/span><span class=\"wpcf7-list-item last\"><input type=\"checkbox\" name=\"cf7s-Information[]\" value=\"Trouble-shooting Assistance\" \/><span class=\"wpcf7-list-item-label\">Trouble-shooting Assistance<\/span><\/span><\/span><\/span><\/li>\n\t\t<li><label for=''>Your Message <em class=\"cf7s-reqd\">*<\/em> <\/label><span class=\"wpcf7-form-control-wrap\" data-name=\"cf7s-comments\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Enter your message\" name=\"cf7s-comments\"><\/textarea><\/span><\/li>\n\t<\/ol>\n\t<p>\n\t\t* Required\n\t<\/p>\n<div class=\"wpcf7-turnstile cf-turnstile\" data-sitekey=\"0x4AAAAAACpmqe1GOuyDt5uN\" data-response-field-name=\"_wpcf7_turnstile_response\" data-appearance=\"interaction-only\" data-theme=\"light\"><\/div>\n\t<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Submit\" \/>\n<\/fieldset><p style=\"display: none !important;\" class=\"akismet-fields-container\" data-prefix=\"_wpcf7_ak_\"><label>&#916;<textarea name=\"_wpcf7_ak_hp_textarea\" cols=\"45\" rows=\"8\" maxlength=\"100\"><\/textarea><\/label><input type=\"hidden\" id=\"ak_js_1\" name=\"_wpcf7_ak_js\" value=\"12\"\/><script>document.getElementById( \"ak_js_1\" ).setAttribute( \"value\", ( new Date() ).getTime() );<\/script><\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"en_gb\"\/><\/form>\n<\/div>\n<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>What are differences between current transducers and Current transformers? Current transducers and current transformers are utilised for the purpose of measuring electrical currents; yet, they exhibit distinctions in terms of their operational principles, applications, and inherent traits. Current Transducers Current Transformer 1. Working Principle of current transformer and current transducer: Current Transformers (CTs) operate based [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[14],"tags":[],"class_list":["post-5229","post","type-post","status-publish","format-standard","hentry","category-knowledge-center"],"aioseo_notices":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.2 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Current transducer vs current transformer - Hangzhi Precision<\/title>\n<meta name=\"description\" content=\"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hangzhiprecision.com\/en_gb\/knowledge-center\/current-transducer-vs-current-transformer\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Current transducer vs current transformer\" \/>\n<meta property=\"og:description\" content=\"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hangzhiprecision.com\/en_gb\/knowledge-center\/current-transducer-vs-current-transformer\/\" \/>\n<meta property=\"og:site_name\" content=\"Hangzhi Precision\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ShenzhenHangzhi\/\" \/>\n<meta property=\"article:published_time\" content=\"2023-08-23T23:44:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-23T02:10:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#\\\/schema\\\/person\\\/5711dcaa661faac60bfec0ad5b6b9847\"},\"headline\":\"Current transducer vs current transformer\",\"datePublished\":\"2023-08-23T23:44:04+00:00\",\"dateModified\":\"2026-01-23T02:10:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/\"},\"wordCount\":553,\"publisher\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/AIT400-SG-0708-300x300.png\",\"articleSection\":[\"Knowledge Center \u2013 Articles &amp; Insights\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/\",\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/\",\"name\":\"Current transducer vs current transformer - Hangzhi Precision\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/AIT400-SG-0708-300x300.png\",\"datePublished\":\"2023-08-23T23:44:04+00:00\",\"dateModified\":\"2026-01-23T02:10:11+00:00\",\"description\":\"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/AIT400-SG-0708-300x300.png\",\"contentUrl\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/AIT400-SG-0708-300x300.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/knowledge-center\\\/current-transducer-vs-current-transformer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Current transducer vs current transformer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/\",\"name\":\"Hangzhi Precision\",\"description\":\"Hangzhi Precision\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#organization\",\"name\":\"Shenzhen Hangzhi Precision Electronics Co., Ltd.\",\"alternateName\":\"Hangzhi Precision\",\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-en-400x400-1.png\",\"contentUrl\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-en-400x400-1.png\",\"width\":400,\"height\":400,\"caption\":\"Shenzhen Hangzhi Precision Electronics Co., Ltd.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ShenzhenHangzhi\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en\\\/#\\\/schema\\\/person\\\/5711dcaa661faac60bfec0ad5b6b9847\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\\\/\\\/www.hangzhiprecision.com\"],\"url\":\"https:\\\/\\\/www.hangzhiprecision.com\\\/en_gb\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Current transducer vs current transformer - Hangzhi Precision","description":"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hangzhiprecision.com\/en_gb\/knowledge-center\/current-transducer-vs-current-transformer\/","og_locale":"en_GB","og_type":"article","og_title":"Current transducer vs current transformer","og_description":"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.","og_url":"https:\/\/www.hangzhiprecision.com\/en_gb\/knowledge-center\/current-transducer-vs-current-transformer\/","og_site_name":"Hangzhi Precision","article_publisher":"https:\/\/www.facebook.com\/ShenzhenHangzhi\/","article_published_time":"2023-08-23T23:44:04+00:00","article_modified_time":"2026-01-23T02:10:11+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#article","isPartOf":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/"},"author":{"name":"admin","@id":"https:\/\/www.hangzhiprecision.com\/en\/#\/schema\/person\/5711dcaa661faac60bfec0ad5b6b9847"},"headline":"Current transducer vs current transformer","datePublished":"2023-08-23T23:44:04+00:00","dateModified":"2026-01-23T02:10:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/"},"wordCount":553,"publisher":{"@id":"https:\/\/www.hangzhiprecision.com\/en\/#organization"},"image":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png","articleSection":["Knowledge Center \u2013 Articles &amp; Insights"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/","url":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/","name":"Current transducer vs current transformer - Hangzhi Precision","isPartOf":{"@id":"https:\/\/www.hangzhiprecision.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#primaryimage"},"image":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png","datePublished":"2023-08-23T23:44:04+00:00","dateModified":"2026-01-23T02:10:11+00:00","description":"Current transducers and current transformers are both used to measure electrical currents, but they differ in their working principles, applications, and characteristics.","breadcrumb":{"@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#primaryimage","url":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png","contentUrl":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2020\/09\/AIT400-SG-0708-300x300.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hangzhiprecision.com\/knowledge-center\/current-transducer-vs-current-transformer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hangzhiprecision.com\/"},{"@type":"ListItem","position":2,"name":"Current transducer vs current transformer"}]},{"@type":"WebSite","@id":"https:\/\/www.hangzhiprecision.com\/en\/#website","url":"https:\/\/www.hangzhiprecision.com\/en\/","name":"Hangzhi Precision","description":"Hangzhi Precision","publisher":{"@id":"https:\/\/www.hangzhiprecision.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hangzhiprecision.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.hangzhiprecision.com\/en\/#organization","name":"Shenzhen Hangzhi Precision Electronics Co., Ltd.","alternateName":"Hangzhi Precision","url":"https:\/\/www.hangzhiprecision.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.hangzhiprecision.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/logo-en-400x400-1.png","contentUrl":"https:\/\/www.hangzhiprecision.com\/wp-content\/uploads\/2023\/08\/logo-en-400x400-1.png","width":400,"height":400,"caption":"Shenzhen Hangzhi Precision Electronics Co., Ltd."},"image":{"@id":"https:\/\/www.hangzhiprecision.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ShenzhenHangzhi\/"]},{"@type":"Person","@id":"https:\/\/www.hangzhiprecision.com\/en\/#\/schema\/person\/5711dcaa661faac60bfec0ad5b6b9847","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4364475fd1358391b3b6be183e2d646b3f2bf894837b788cef08b53472ba9498?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/www.hangzhiprecision.com"],"url":"https:\/\/www.hangzhiprecision.com\/en_gb\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/posts\/5229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/comments?post=5229"}],"version-history":[{"count":0,"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/posts\/5229\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/media?parent=5229"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/categories?post=5229"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hangzhiprecision.com\/en_gb\/wp-json\/wp\/v2\/tags?post=5229"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}